Final rule on water used with produce

Standards for Produce for Human Consumption – Water

fda.gov   02 December 2015

The final rule for produce safety was finalized November 2015.  One of the key requirements covers the water used in agriculture.

1. Agricultural Water

  • Water quality: The final rule adopts the general approach to water quality proposed in the supplemental rule, with some changes. The final rule establishes two sets of criteria for microbial water quality, both of which are based on the presence of generic E. coli, which can indicate the presence of fecal contamination.
    • No detectable generic E. coli are allowed for certain uses of agricultural water in which it is reasonably likely that potentially dangerous microbes, if present, would be transferred to produce through direct or indirect contact. Examples include water used for washing hands during and after harvest, water used on food-contact surfaces, water used to directly contact produce (including to make ice) during or after harvest, and water used for sprout irrigation. The rule establishes that such water use must be immediately discontinued and corrective actions taken before re-use for any of these purposes if generic E. coli is detected. The rule prohibits use of untreated surface water for any of these purposes.
    • The second set of numerical criteria is for agricultural water that is directly applied to growing produce (other than sprouts). The criteria are based on two values, the geometric mean (GM) and the statistical threshold (STV). The GM of samples is 126 or less CFU of generic E.coli per 100 mL of water and the STV of samples is 410 CFU or less of generic E.coli in 100 mL of water.  More information here.
  • Testing: The final rule adopts the general approach to testing untreated water used for certain purposes proposed in the supplemental notice, with some changes. The rule still bases testing frequency on the type of water source (i.e. surface or ground water).
    • In testing untreated surface water—considered the most vulnerable to external influences—that is directly applied to growing produce (other than sprouts), the FDA requires farms to do an initial survey, using a minimum of 20 samples, collected as close as is practicable to harvest over the course of two to four years. The initial survey findings are used to calculate the GM and STV (these two figures are referred to as the “microbial water quality profile”) and determine if the water meets the required microbial quality criteria.
      •  After the initial survey has been conducted, an annual survey of a minimum of five samples per year is required to update the calculations of GM and STV.
      • The five new samples, plus the previous most recent 15 samples, create a rolling dataset of 20 samples for use in confirming that that the water is still used appropriately by recalculating the GM and STV.
    • For untreated ground water that is directly applied to growing produce (other than sprouts), the FDA requires farms to do an initial survey, using a minimum of four samples, collected as close as is practicable to harvest, during the growing season or over a period of one year. The initial survey findings are used to calculate the GM and STV and determine if the water meets the required microbial quality criteria.
      • After the initial survey has been conducted, an annual survey of a minimum of one sample per year is required to update the calculations of GM and STV.
      • The new sample, plus the previous most recent three samples, create a rolling dataset of four samples for use in confirming that that the water is still used appropriately by recalculating the GM and STV.
    • For untreated ground water that is used for the purposes for which no detectable generic E. coli is allowed, the FDA requires farms to initially test the untreated ground water at least four times during the growing season or over a period of one year. Farms must determine whether the water can be used for that purpose based on these results.
      • If the four initial sample results meet the no detectable generic E. coli criterion, testing can be done once annually thereafter, using a minimum of one sample. Farms must resume testing at least four times per growing season or year if any annual test fails to meet the microbial quality criterion.
    • There is no requirement to test agricultural water that is received from public water systems or supplies that meet requirements established in the rule (provided that the farm has Public Water System results or certificates of compliance demonstrating that the water meets relevant requirements), or if the water is treated in compliance with the rule’s treatment requirements.

Let Daily Laboratories help you meet the requirements.  Give us a call.